Show simple item record

dc.contributor.authorSenok, Abiola
dc.contributor.authorAlsuwaidi, Hanan
dc.contributor.authorHan, Aaron
dc.contributor.authorAl Heialy, Saba
dc.contributor.authorLoney, Tom
dc.contributor.authorAlsheikh-Ali, Alawi
dc.date.accessioned2021-08-03T10:08:53Z
dc.date.available2021-08-03T10:08:53Z
dc.date.issued2020
dc.identifier.other204-2020.69
dc.identifier.urihttps://repository.mbru.ac.ae/handle/1/380
dc.description.abstractPurpose: With the easing of restriction measures, repeated community-based sampling for tracking new COVID-19 infections is anticipated for the next 6 to 12 months. A non-invasive, self-collected specimen like saliva will be useful for such public health surveillance. Investigations on the use of saliva for SARS-CoV-2 RT-PCR have largely been among COVID-19 in-pa\tients and symptomatic ambulatory patients with limited work in a community-based screening setting. This study was carried out to address this paucity of data and reported discrepancies in diagnostic accuracy for saliva samples. Patients and Methods: From 29th June to 14th July 2020, adults presenting for COVID- 19 testing at a community-based screening facility in Dubai, United Arab Emirates were recruited. Clinical data, nasopharyngeal swab in universal transport media and drooling saliva in sterile containers were obtained. Reverse transcriptase PCR amplification of SARS-CoV-2 RdRp and N genes was used to detect the presence of the SARS-CoV-2 virus. Results: Of the 401 participants, 35 (8.7%) had viral detection in at least one specimen type and the majority (n=20/35; 57.1%) were asymptomatic. Both swab and saliva were positive in 19 (54.2%) patients, while 7 (20.0%) patients had swab positive/saliva negative results. There were 9 (25.7%) patients with saliva positive/swab negative result and this included 5 asymptomatic COVID-19 patients undergoing repeat screening. Using the swab as the reference gold standard, the sensitivity and specificity of saliva were 73.1% (95% CI 52.2–88.4%) and 97.6% (95% CI 95.5–98.9%) while the positive and negative predictive values were 67.9% (95% CI 51.5–80.8%) and 98.1% (95% CI 96.5–99.0%), respectively. Conclusion: The findings suggest good diagnostic accuracy for saliva and feasibility of utilization of specimen without transport media for SARS-CoV-2 RT-PCR. Saliva represents a potential specimen of choice in community settings and population-based screening.en_US
dc.language.isoenen_US
dc.subjectSARS-CoV-2en_US
dc.subjectNasopharyngeal swaben_US
dc.subjectMolecular testen_US
dc.subjectPopulation-based screeningen_US
dc.subjectSalivaen_US
dc.titleSaliva as an Alternative Specimen for Molecular COVID-19 Testing in Community Settings and Population-Based Screeningen_US
dc.typeArticleen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record