Browsing by Author "Amre R., Atmeh"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Publication The effect of irrigation solution temperature and novel heat-treated rotary files on apical debris extrusion and canal preparation time(2024) Amre R., AtmehAbstract: This study aimed to compare apical debris extrusion and canal preparation time with ProTaper Gold (PTG) and ProTaper Ultimate (PTU) files at different temperatures. Mesio-buccal roots of 60 mandibular first molars were distributed into six groups depending on the file type (PTG, PTU) and irrigation solution temperature (20, 37, 45°C). During instrumentation, extruded debris were collected and weighed to measure the mass in milligrams. The canal preparation time was recorded in seconds. ANOVA followed by Bonferroni post-hoc tests were used for analysis. The amount of debris extrusion was significantly higher in PTU, which was affected by the irrigation solution temperature (p <0.05). The difference in canal preparation time was not significant between the two file systems, however, it was significant between the different temperatures (p=0.001). Both file systems had shorter canal preparation times at 20°C. The irrigation solution temperature could influence the debris extrusion and time of canal preparation.Publication Inflammatory response to epoxy resin and calcium silicate sealers preheated with different temperatures: an in vivo study(2023-02) Amre R., AtmehAbstract Objective: To determine the impact of heat exposure of different sealers on inflammatory cytokine secretions and tissue response in vivo. Materials and methods: Silicone tubes were prefilled with epoxy resin (ER) or calcium silicate (CS) sealers, preheated at 37, 60, or 120 °C, and implanted in rat subcutaneous site. Peri-implant exudate and tissue were analyzed after 1 and 4 weeks for cytokine secretions and tissue organization. Results: At 1 week, 120 °C-preheated CS and ER induced higher secretions of tumor necrosis factor alpha (TNF-α) and interleukin 6 (IL-6), respectively, as compared to sham/empty tube groups. At 4 weeks, whereas TNF-α secretion was reduced in CS, it increased in ER group, particularly for 120 °C. Both sealers revealed high IL-6 after 4 weeks as compared to sham/empty tube, and generally, higher IL-6 secretions were associated with ER. Histology at 1 week revealed lower degree of inflammatory infiltrate in the groups of the highest preheating temperature (120 °C). Nonetheless, at 4 weeks, whereas fibrous capsule area and inflammatory infiltrate remained low in the CS120 group, they were high in ER120. Conclusion: Preheating ER sealer to 120 °C induced high and prolonged secretion of proinflammatory cytokines (TNF-α and IL-6), whereas this effect was transient for the CS sealer. This was associated with increased fibrous capsule and inflammatory infiltrate in response to 120 °C-preheated ER. Clinical relevance: Heat-induced changes in sealer properties alter the inflammatory response in vivo, which may affect the clinical outcome. This will not only help appropriate selection of obturation technique for different sealers, but also for optimizing the properties of new generation of sealers.Publication Reliability of sealer penetration measurement methods and assessment of dentine penetrability after endodonticre treatment: A correlation in vitro study(2024) Amre R., AtmehAbstract: This study evaluated the reliability of sealer penetration measurement methods used with confocal laser scanning microscopy in correlation with the percentage of residual root filling and examined the effect of residual root-filling material on dentine penetrability after retreatment. Extracted teeth were randomly divided into different groups according to the obturation sealer used (n = 6); Bio Root RCS; MTA Fillapex; Bio-C and AH Plus. Root-filling material was removed before the secondary chemo-mechanical preparation and obturation using fluorescein labelled AH Plus. Multiplemicro-computed tomography scans were obtained followed by confocal laser scanning microscopy to measure the penetration of the labelled sealer into the dentinal tubules using four different methods. Measuring sealer penetration into radicular dentine using the penetration percentage method was found to be the most reliable. Dentine penetrability during retreatment did not seem to be affected by the type of residual root-filling material.